Turning on the unit, Compact version (units acquired since june 2008), Remote version – ADS Environmental Services PrimeProbe2 QR 775016 A0 User Manual

Page 10: Compact version ( units acquired since june 2008 )

Advertising
background image

PrimeProbe2 User Manual

6

Turning On the Unit

ADS delivers the PrimeProbe2 in the OFF condition. The user must turn
it on before going to the first installation site, as described in the following
sections.

Compact Version (units acquired since June 2008)

1.

Launch the PrimeWorks

®

software.

2.

Connect the PrimeProbe2 to the PC/laptop running the software
using the communications cable.

3.

Select the PrimeProbe2 > Shipping > Wake up menu option.
The software will initiate communications with the PrimeProbe2 to
bring it out of Sleep mode. The probe is now ready for use.

Compact Version (units acquired prior to June 2008)

1.

Using the 5mm Allen key (supplied by ADS), remove the 4 screws
securing the rear cover of the converter.

2.

Locate the two small switches left of center of the circuit board and
in front of the battery. Place them in the LEFT position.

3.

Replace the cover and the 4 screws, and then tighten the screws
with the Allen key securely and evenly.

Remote Version

1.

Using the 5mm Allen key (supplied by ADS), remove the 4 screws
securing the rear cover of the converter.

2.

Locate the two small switches immediately behind the
communications jack socket. Place these switches in the LEFT
position.

3.

Replace the cover and the 4 screws, and then tighten the screws
with the Allen key securely and evenly.

Note:

Tighten all the screws fully to prevent water ingress from

occurring.

Advertising