PrimeProbe2 User Manual

7

Site Selection

The PrimeProbe2 can be used on pipes with internal diameters from 3.15
to 314.96 inches (80 to 8000mm) at 1/8 diameter insertion depth, based on
the insertion length of the selected probe. The following table indicates
the 4 different insertion lengths of the PrimeProbe2 and the pipe sizes in
which they can operate. The PrimeProbe2 can be located at one of three
depth positions:

½-pipe diameter, 1/8-pipe diameter, or 7/8-pipe diameter.

Size of

PrimeProbe2

Internal Diameters

of Pipes at 1/8

Diameter Insertion

Depth

Size of

PrimeProbe2

Internal Diameters

of Pipes at 1/2

Diameter Insertion

Depth

11.81 inches

(300 mm)

3.15 to 78.74 inches

(80 to 2000 mm)

11.81 inches

(300 mm)

3.15 to 23.62 inches

(80mm to 600mm)

19.69 inches

(500 mm)

3.15 to 78.74 inches

(80 to 2000 mm)

19.69 inches

(500 mm)

3.15 to 39.37 inches

(80 to 1000 mm)

27.56 inches

(700 mm)

3.15 to 220.47 inches

(80 to 5600 mm)

27.56 inches

(700 mm)

3.15 to 55.12 inches

(80 to 1400 mm)

39.37 inches

(1000 mm)

3.15 to 314.96 inches

(80 to 8000 mm)

39.37 inches

(1000 mm)

3.15 to 78.74 inches

(80 to 2000 mm)

Before installing the PrimeProbe2, determine the direction of the flow in
the pipe. The PrimeProbe2 must be installed in the correct direction.
Using the symbols on the nameplate of the sensor (

to +) for reference,

the PrimeProbe2 is installed correctly when the flow in the pipe travels
from

to +.