background image

PrimeProbe2 User Manual

4

Technical Specifications

Parameter

Specification

Pipe Sizes

3.2 to 315.0 inches (80 mm to 8000 mm)

at 1/8 pipe

diameter (insertion depth) installation

Measurement Range

Bi-directional from 0.03 to 16.40 feet per second (0.01 m/s
to 5 m/s) (Maximum may be lower based on insertion length
and pipe position.)

Accuracy; Point

Velocity

Flow

±

0.0066 feet per second (

±

2mm/sec) or

±

2%, whichever is

the greater.

Refer to ISO 7145-1982

Repeatability

±

0.5% of velocity

Flow Determination

Assumes fully developed flow profile; ISO 7145-1982
reference

Measurement

Sampling

Continuous or programmable from 1 to 90 seconds

Minimum Fluid

Conductivity

5

µ

S/cm

Process Connection

1-inch (25-mm) BSP (British Standard Pipe)

Pipeline Pressure

Rating

232 psi

Sensor Material

PTFE (

polytetrafluoroethylene)

Body Material

SS304

Electrode Materials

SS316

Flow Temperature

32

º

to 176

º

F (0 to 80

º

C)

Safety

Probe fitted with anti-bounce chain

Pressure Tapping

Female quick-release connector

Adjustment Method

5 mm Allen key (supplied by ADS)

fits all screws

Protection

IP68

Batteries

Type: Lithium batteries

Life:

3 years (depending on sampling period and usage)

Output: Signal

Units

Connection

Pulses proportional to velocity/flow rate - maximum frequency
32 Hz

User-selectable

MIL-spec connector

Communications

USB