Setting up a static ip address on the flowstation – Baseline Systems FlowStation User Manual

Page 25

Advertising
background image

Baseline FlowStation User Manual

Example:

In AM/PM format

10:00A and 10:00P

In 24 hour format

10:00 and 22:00

6. When you have finished making changes, press the RUN button.

Setting Up a Static IP Address on the FlowStation

In order to have the FlowStation communicate with the BaseStation 3200 controllers in the shared

flow group, the FlowStation must be connected to a network with a supported communication

module. You need to assign a static IP address to the FlowStation to enable the BaseStation 3200

irrigation controllers in the shared flow group to connect to the FlowStation.

1. Make sure the communication module in your FlowStation is powered up and communicating

with the network.

2. On the FlowStation, press the System Setup button. The System Setup menu displays.

3. Press the  button to highlight the Network Setup option, and then press the OK button to

select it. The Network Setup menu displays.

4. The IP Setup option should be highlighted. If it is not highlighted, press the  or  button to

highlight it, and then press the OK button. The IP Setup screen displays.

5. Press the + or button to remove the

checkmark in the DHCP Enabled field. The

fields for the network settings display.

Note: For an explanation of the settings, refer

to Viewing the IP Information Screen on the

FlowStation on page 22.

6. Determine the static IP address that you will

assign to the FlowStation. The IP address is based on the IP addresses of the other devices on

the network, but it must have a unique last digit.

Example: The devices in your shared flow group are connected to a stand-alone network that

does not have Internet access. The communication modules in your FlowStation and

controllers have factory-assigned IP addresses in the range 192.168.111.100 -

192.168.111.105. You can set the static IP address on the FlowStation to 192.168.111.106.

7. Press the  button to highlight the first digits in the IP Addr field.

Press the  or  button to move to the digits that you want to change.

Press the + or button to change the value in the field.

Note: To rapidly increase or decrease the value, press and hold the + button or the button.

8. Press the  button to move to the Mask field. Use the procedure described in step 7 to move

within the digits and change the values. A typical value for the Subnet Mask is 255.255.255.0

Note: Set the Subnet Mask for all devices in your shared flow group to the same value.

9. Press the  button to move to the Gateway field. Use the procedure described in step 7 to

move within the digits and change the values.

4 – Configuring the FlowStation

Page 21

Advertising