Dell POWEREDGE R610 User Manual

Page 25

Advertising
background image

About Your System

25

E1216

3.3V

Regulator

failure.

Reseat PCIe

cards.

3.3V voltage regulator has

failed.

Remove and reseat the

PCIe expansion cards. If

the problem persists, see

"Troubleshooting

Expansion Cards."

E1229

CPU # VCORE

Regulator

failure.

Reseat CPU.

Specified processor

VCORE voltage regulator

has failed.

Reseat the processor(s).

See "Troubleshooting the

Processors."
If the problem persists,

see "Getting Help."

E122A

CPU # VTT

Regulator

failure.

Reseat CPU.

Specified processor VTT

voltage regulator has failed.

Reseat the processor(s).

See "Troubleshooting the

Processors."
If the problem persists,

see "Getting Help."

E122C

CPU Power

Fault. Power

cycle AC.

A power fault was detected

when powering up the

processor(s).

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help."

E122D

Memory

Regulator #

Failed.

Reseat DIMMs.

One of the memory

regulators has failed.

Reseat the memory

modules. See

"Troubleshooting System

Memory."

E122E

On-board

regulator

failed. Call

support.

One of the on-board

voltage regulators failed.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help."

E1310

Fan ## RPM

exceeding

range. Check

fan.

RPM of specified fan is

outside of the intended

operating range.

See "Troubleshooting

System Cooling

Problems."

Table 1-1. LCD Status Messages

(continued)

Code

Text

Cause

Corrective Actions

Advertising