SAFETY CHECK-OUT

After correcting the original service problem, perform the following

safety checks before releasing the set to the customer.

1.

Check the area of your repair for unsoldered or poorly-soldered
connections. Check the entire board surface for solder splashes
and bridges.

2.

Check the interboard wiring to ensure that no wires are
"pinched" or contact high-wattage resistors.

3.

Look for unauthorized replacement parts, particularly

transistors, that were installed during a previous repair. Point
them out to tlie customer and recommend their replacement.

4.

Look for parts which, though functioning, show obvious signs

of deterioration. Point them out to the customer and
recommend their replacement.

.3. Check the line cord for cracks and abrasion.

Recommend the replacement of any such line cord to the
customer.

6.

Check tile B-i- voltage to see it is at the values specified.

7.

C'lieck the antenna terminals, metal trim, "metallized" knobs,
screws, and all other exposed metal parts for AC leakage.
Check Icakasie as described below.

To Exposed Metal

Parts on Set

\

I.

,-J-,

AC

0.f5pF=

1.51^1 i /

< .: j ’

I J

(U./O V)

Earth Ground

Fig. A. Using an AC voltmeter to check AC leakage.

LEAKAGETEST

Tile AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0..5mA (300 microampers).
Leakage current can be measured by any one of three methods.

1.

A commercial leakage tester, such as the Simpson 220 or RC’A
TW-540A. Follow the manufacturers' instrtictions to use these
instruments.

2.

A battery-operated AC milliammeter. The Data Precision 243
digital multimeter is suitable for this job.

3.

Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The "limit" indication
is 0.75V, so analog meters must have an accurate low voltage

scale. The Simpson 250 and Sanwa SH-63Trd are examples
of a passive VOM that is suitable. Nearly all battery operated

digital multimeters that have a 2V AC range arc suitable. (See
Fig. A)

SAFETY-RELATED COMPONENT WARNING!!

COMPONENTS IDENTIFIED BY MARK /t OR DOTTED LINE WITH
MARK st ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS

APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS

ATTENTION AU COMPOSANT AYANT RAPPORT

À LA SÉCURITÉ!

LES COMPOSANTS IDENTIFÉS PAR UNE MARQUE

A SUR LES

DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE
REMPLACER CES COMPOSANTS QUE PAR DES PIÈSES SONY
DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU

1-ЧАМО I cro c»i 100СЛЯ1ГМТС DI im irQ РДР QOMV