CLI Command List

Message:

Alarms:

Current Accumulated

------- -----------

sys power off off

sys brownout off off

sys redun off off

sys reset off off

v35 rts off off

v35 llb off off

v35 v54 off off

t1 (T1#1) carrier off off

t1 (T1#1) csuloop off off

t1 (T1#1) unframed off off

t1 (T1#1) sync off off

t1 (T1#1) yellow off off

t1 (T1#1) bpv off off

t1 (T1#1) ses off off

t1 (T1#1) unavail off off

t1 (T1#1) fdlline off off

t1 (T1#1) fdlpay off off

t1drop (T1#2) carrier off off

t1drop (T1#2) csuloop off off

t1drop (T1#2) unframed off off

t1drop (T1#2) sync off off

t1drop (T1#2) yellow off off

t1drop (T1#2) bpv off off

t1drop (T1#2) ses off off

t1drop (T1#2) unavail off off

t1drop (T1#2) fdlline off off

t1drop (T1#2) fdlpay off off

Item

Description

Current

Indicates current alarm state

Accumulated

Indicates if any alarms have occurred (accumulated) since the
last time the alarm status was read. This flag is cleared (set to
“off”) after reading.

off

No alarms occurred

on

One or more alarms occurred

sys power

Hard reset or power-on detected

sys brownout

Low input power (–48 VDC input) detected

sys redun

Redundant T1 switch occurred
(This feature is not supported by the Access Navigator)

sys reset

Soft reset detected