Transmitter Flow-Control Inputs

The IIPC implements the Interlaken in-band flow control mechanism. This mechanism

communicates XON/XOFF for different channels using the In-Band Flow Control bits of Control

words. Additionally, the Multiple-Use bits of Control Words may be used in a similar manner as

described in the

Transmitter Multiple-Use Bits

and

Receiver Multiple-Use Bits

sections.

Inside each Interlaken Control Word are 16 bits of In-Band Flow Control information, bits[55:40],

and a Reset Calendar bit, bit[56]. These bits are shared over the calendar length as described

below. The Interlaken Core has a calendar length of 256 and provides one transmit bit and one

receive bit for each calendar entry.
By definition, XON is represented by 1, and XOFF is represented by 0 for both the Transmitter

and the Receiver. All signals are synchronous with the rising-edge of clk and a detailed

description of each signal follows.
ctl_tx_fc_stat[255:0]
The user is given full flexibility to implement any mechanism to handle system wide flow

control. The IIPC Transmitter simply inputs the user supplied calendar information and packs it

into the Interlaken Control words and transmits it over the link. This mechanism allows the user

to take into account system wide parameters and optimize the buffering by implementing the

most optimum flow control mechanism.
The operation is as described in the Interlaken Protocol Definition. The first calendar entry,

ctl_tx_fc_stat[0], is sent in bit[55] of a Control Word with the Reset Calendar bit, bit[56], set to a

value of 1. The next calendar entry, ctl_tx_fc_stat[1], is sent in bit[54] of the same Control Word

and so on. The 17th calendar entry, ctl_tx_fc_stat[16], is sent in bit[55] the next Control Word that

has the Reset Calendar bit, bit[56], set to a value of 0, and so forth.
ctl_tx_fc_callen[3:0]
The flow control calendar length can be shorter than the maximum calendar length supported by

the IIPCwith the help of ctl_tx_fc_callen parameter. When ctl_tx_fc_callen is a value of 0, the

calendar length become 16 and only ctl_tx_fc_stat[15:0] are used. When ctl_tx_fc_callen is a value

of 1, the calendar length become 32 only ctl_tx_fc_stat[31:0] are used. And so forth. The valid

settings for calendar length are as follows:

0x0 = 16 entries

0x1 = 32 entries

0x3 = 64 entries

0x7 = 128 entries

0xF = 256 entries

All other values are reserved.