APD-100 Automatic Powder Dispenser User Instructions

Configuration

9.

Type in a value between 0.3 grains and 3.00 grains and press the ENTER key
to accept the value displayed…

ZPRX.XX is displayed. This is a Zero Point Return parameter. If, after
you empty the powder scoop and return it to the scale platter, the weight
is less than or equal to this value the APD-100 will automatically restart
a new charge cycle. If the weight is more than this value the display will
show ERROR. Values must be between 0.1 and 3.00 grains. 0.3 is the
default value.

10.

Type in a value between 0.1 grains and 3.00 grains and press the ENTER key
to accept the value displayed…

The next powder type is displayed. Repeat steps

2

through

10

for each

powder type you will use.

11.

Press the ZERO/EXIT key to return to the normal weighing mode.