D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N

Model 200iP/250iP Dynamometer

Version 3

Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers

15

R

OOM

L

AYOUT

—M

ODEL

200

I

P/250

I

P D

YNO

Use the following information to locate the necessary dyno equipment, power outlets,
compressed air, and properly set up your dyno room.
For more detailed information about the pit requirements, refer to the pit
specifications (P/N 98229102) you received from your salesman.

Note: The pit must be provided with exhaust ventilation at a rate of not less than
1CFM per ft.

2

of floor area (26CFM for the 250iP pit) taken from a point 300 mm

(12 in.) off the floor of the pit at all times that the building is occupied or when
vehicles are parked over this area.

Figure 8: Room Layout—Model 200iP/250iP Top View

Pd186

284.48 cm (112.00 in.)*

121.92 cm 
(48.00 in.)

60.96 cm (24.00 in.)

min. dimension

standard carriage 

177.39 cm
(69.84 in.)

31.09 cm 

(12.24 in.)*

29.84 cm (11.75 in.)*

60.33 cm (23.75 in.)*

standard carriage 

320.04 cm

(126.00 in.)*

standard carriage 

345.44 cm

(136.00 in.)*

min. dimension

extended carriage 

220.98 cm
(87.00 in.)

extended carriage 

365.76 cm

(144.00 in.)*

extended carriage 

436.88 cm

(172.00 in.)*

*Dimensions are given for reference only and will vary with room size.

provide compressed air for the:

•optional air brake

•optional AFR‐4 pump

provide an outlet for dyno power