Testing for correct voltages – Dynojet 250ix: Pre-Installation Guide User Manual

Page 42

Advertising
background image

Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers

A P P E N D I X B
Locations Using 60 Hz Power (North America and Japan)

B-4

T

ESTING

FOR

C

ORRECT

V

OLTAGES

You must test the receptacle for proper voltages before the dyno is connected to the
outlet.

If the voltage readings do not match the following table, DO NOT connect the
dyno. You must have a licensed electrician correct the power connection.
Connecting the dyno to the incorrect voltage can result in damage to the dyno
and will void the dyno warranty. Contact Dynojet with any questions.

Using a voltmeter that is capable of measuring AC voltage, measure between the
points listed below and verify that the correct voltages are present.

*If using two of the three phase lines of a 120/208V 3 phase Y system, then expect to
see 187V to 225V.

Figure B-1: Dedicated Power Receptacle

probe 1

probe 2

desired voltage measurement

2

4

216V to 260V*

1

4

108V to 130V

1

2

108V to 130V

1

3

<5V

3

box

<5V

4

1

3

2

Advertising