Room layout-model 250ipx dyno, Px d – Dynojet 250ix: Pre-Installation Guide User Manual

Page 31

Advertising
background image

D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N

Model 250iPX Dynamometer

Version 3

Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers

23

R

OOM

L

AYOUT

—M

ODEL

250

I

PX D

YNO

Use the following information to locate the necessary dyno equipment, power outlets,
compressed air, and properly set up your dyno room.
For more detailed information about the pit requirements, refer to the pit
specifications (P/N 98229104) you received from your salesman.

Note: The pit must be provided with exhaust ventilation at a rate of not less than
1CFM per ft.

2

of floor area (26CFM for the 250iP pit) taken from a point 300 mm

(12 in.) off the floor of the pit at all times that the building is occupied or when
vehicles are parked over this area.

Figure 15: Room Layout—Model 250iPX Top View

158.75 cm (62.50 in.)*

*Dimensions are given for reference only and will vary with room size.

60.96 cm (24.00 in.)

182.88 cm (72.00 in.)

365.76 cm (144.00 in.)*

40.64 cm (16.00 in.)*

30.48 cm

(12.00 in.)*

min. dimensions for

standard carriage 

177.39 cm (69.84 in.) 

extended carriage 

220.98 cm (87.00 in.)

standard carriage 

320.04 cm (126.00 in.) 

extended carriage 

365.76 cm (144.00 in.)

457.20 cm

(180.00 in.)*

provide compressed air for the:

•optional air brake

•optional AFR‐4 pump

provide an outlet for dyno power