Hi-6105 operation – ETS-Lindgren HI-6153 Electric Field Probe User Manual
Page 40
40 |
Laser-Powered Field Probes: HI-6105 Electric Field Probe
Physical Interface:
Duplex optical fiber
(62.5 micron multimode)
FC connectors for laser cable,
integral 1-m optical cable
ST connector for transmitter cable,
integral 1-m optical cable
Probe Mount:
1/4–20 UNC (internal thread)
Dimensions
Housing:
32 mm x 32 mm x 32 mm
1.26 in x 1.26 in x 1.26 in
Probe Shields:
43 mm (1.69 in)
Weight:
0.08 kg (2.6 oz.)
Environmental
Operating Temperature:
10
°
C to 40
°
C
50
°
F to 104
°
F
Humidity:
5% to 95% relative humidity,
non-condensing
HI-6105
O
PERATION
The HI-6105 can be used with the HI-6100 Field Monitor. It can also be
connected to a personal computer using an optional HI-6113 Laser Data
Interface (LDI) and ProbeView™ Laser software.
For a list and description of communication and information transfer protocols,
including command structure, probe commands, and HI-6113 commands, see
Appendix D: Operating Protocols
on page 101.