Hi-6105 operation – ETS-Lindgren HI-6153 Electric Field Probe User Manual

Page 40

Advertising
background image

40 |

Laser-Powered Field Probes: HI-6105 Electric Field Probe

Physical Interface:

Duplex optical fiber

(62.5 micron multimode)

FC connectors for laser cable,
integral 1-m optical cable

ST connector for transmitter cable,
integral 1-m optical cable

Probe Mount:

1/4–20 UNC (internal thread)

Dimensions

Housing:

32 mm x 32 mm x 32 mm
1.26 in x 1.26 in x 1.26 in

Probe Shields:

43 mm (1.69 in)

Weight:

0.08 kg (2.6 oz.)

Environmental

Operating Temperature:

10

°

C to 40

°

C

50

°

F to 104

°

F

Humidity:

5% to 95% relative humidity,
non-condensing

HI-6105

O

PERATION

The HI-6105 can be used with the HI-6100 Field Monitor. It can also be
connected to a personal computer using an optional HI-6113 Laser Data
Interface (LDI) and ProbeView™ Laser software.

For a list and description of communication and information transfer protocols,
including command structure, probe commands, and HI-6113 commands, see
Appendix D: Operating Protocols

on page 101.

Advertising