6 environmental specifications, 7 mtbf – Kontron JRexplus-DC User Manual

Page 15

Advertising
background image

KTD-S0008-F Page

10 Specifications

JRexplus-DC User's Guide

3.6

Environmental Specifications

Temperature

Operating:

Ambient temperature: 0 to +40°C (passive cooler with no airflow)

Ambient temperature: 0 to +60°C

1)

(active cooler with appropriate airflow)

Non operating:

Ambient temperature: -10 to +85°C

Note:

1)

It is the customer's responsibility to provide sufficient airflow around each of the components to keep them within the

allowed temperature range.

Humidity

Operating:

10% to 90% (non condensing)

Non operating:

5% to 95% (non condensing)

3.7

MTBF

The following MTBF (Mean Time Before Failure) values were calculated using a combination of
manufacturer’s test data, if the data was available, and the Telcordia (Bellcore) issue 2 calculation for the
remaining parts. The Telcordia calculation used is “Method 1 Case 3” in a ground benign, controlled
environment (GB,GC). This particular method takes into account varying temperature and stress data and
the system is assumed to have not been burned in. Figure 1 below shows MTBF de-rating for the E1
temperature range in an office or telecommunications environment. Other environmental stresses
(extreme altitude, vibration, salt water exposure etc.) lower MTBF values.

»

System MTBF(hours) = 227228 @ 40°C

Advertising