34

Parallel Port Interface

JRexplus-DC User's Guide

17 Parallel Port Interface

The JRexplus-DC incorporates a parallel port that can be set to uni-/bidirectional and supports EPP/ECP
operating modes.

17.1 Connector

The parallel port is available through the connector X20 (32 pins). A DSUB25 adapter cable is deliverable
from KONTRON (KAB-DSUB25-2, part number 61033).

Header

Pin

Signal Name

Function

DSUB25

1

VCC

1)

Power +5V

N.C.

12

/AFD

Autofeed

14

13

/STB

Strobe

1

14

/ERR

Error

15

15

D0

Data 0

2

16

/INIT

Init

16

18

D1

Data 1

3

19

/SLIN

Select in

17

20

D2

Data 2

4

21

D3

Data 3

5

23

D4

Data 4

6

24

D5

Data 5

7

25

D6

Data 6

8

26

D7

Data 7

9

28

/ACK

Acknowledge

10

29

/BUSY

Busy

11

30

PE

Paper out

12

31

/SLCT

Select out

13

2, 11

GND

Ground

18 - 25

17, 22

GND

Ground

18 - 25

1

32

27,32

GND

Ground

18 - 25

Note:

1)

To protect the external power lines of peripheral devices make sure that

- the wires have the right diameter to withstand the maximum available current.

- to enclosure of the peripheral device fulfills the fire-protecting conditions of IEC/EN 60950.