22 power and thermal management, 1 speedstep technology, 2 c-state control – Kontron JRexplus-DC User Manual

Page 44: 3 hyper-threading technology, 4 fan interface

Advertising
background image

KTD-S0008-F

Page 39

Power and Thermal Management

JRexplus-DC User's Guide

22 Power and Thermal Management

22.1 SpeedStep Technology

The Intel

®

Atom processor offers the Intel

®

Enhanced SpeedStep

TM

technology that automatically switches

between maximum performance mode and battery optimized mode depending on the needs of the appli-
cation being run. When powered by a battery or running in idle mode the processor drops to lower fre-
quencies conserving battery life while maintaining a high level of performance. The previous frequency is
set back automatically when the operating mode changes.

22.2 C-State Control

The Intel

®

chipset has been implemented the control for dynamically starting and stopping system clocks

and power. The states are passing through C0 (full on) to C4 one after another. The C-state ends when a
break event occurs (e.g. an IRQ or SMI).

22.3 Hyper-Threading Technology

Intels

®

Hyper-Threading technology boosts system performance without higher clock rates or adding more

processors which is also an optimization of the power consumption. Hyper-Threading works by duplicating
instructions streams, called threads. This allows a CPU to pretend to be two logical processors on the
operating system which must support this technology. Individually the logical processors can be halted or
interrupted or can execute a thread independently of the other logical unit.

22.4 Fan Interface

If a fan is added use this interface to connect a fan to cool off the CPU. The connector only supports 5V
fans. A three pin fan includes a pulse output (sense) which allows the control of fan speed.

22.4.1 Connector

The fan interface is available through connector J29.

Header

Pin

Signal Name

Function

1

SENSE

Speed monitoring

2

VCC

1)

Power +5V

3

GND

Ground

Note:

1)

To protect the external power lines of peripheral devices make sure that

- the wires have the right diameter to withstand the maximum available current.

- the enclosure of the peripheral device fulfills the fire-protecting conditions of IEC/EN 60950.