10. Maintenance and Prevention

KISS 1U Short – User’s Guide (V1.10)

4.

Remove the dirty filter mat (Fig. 23, pos. 2 or Fig. 25).

5.

To clean the filter mat:

‰

Rinse in water (up to approx. 40°C; you may add mild-duty commercial detergent).

‰

It is also possible to beat it out, vacuum it or blast it with warm compressed air.

‰

If the filter is soiled with greasy dust, you should rinse it with warm water with degreaser added. Do not clean the
filter mat with a piercing jet of water or wring it out.

6.

After cleaning and drying the filter mat, replace it into the filter mat holder. Insert the positioning lugs of the filter
mat holder (Fig. 26, pos. 7) into the positioning holes (Fig. 24, pos. 6) at the front side of the chassis.

7.

Tighten the knurled screws to secure the filter mat holders to the chassis.

When inserting the filter mat, ensure that the denser side of the mat is facing the fans.

Defective components may be replaced only by Kontron original spare parts.

Part number of the filter mat: 1017-2544