Cable Grounding
5
Figure 2-2. System 104 Wiring Diagram, Inside Enclosure
2.4
Cable Grounding
Cables routed through the cord grips should be grounded against the indicator enclosure. Follow cable grounding
instructions in the 920i Installation and Operation Manua
2.5
Parts Kit Contents
Part No
Description
QTY
14626
Kep nuts, 8-32NC (6)
6
15133
Lock washers, No. 8, type A (6)
6
15631
Cable ties (4 single A/D, 6 dual A/D)
4
15665
Reducing glands for 1/2 NPT cord grips (11)
11
15887
6-position screw terminal for load cell connection (1-single A/D, 2-dual A/D)
1
19538
Cord grip plugs (10-single A/D, 9-dual A/D)
10
94422
Capacity Label (1-single A/D, 2-dual A/D)
1
53075
Cable shield ground clamps (6)
6
70599
6-position screw terminals for J2 and J10 (2)
2
71125
3-position screw terminal for J11 (1)
1
71126
4-position screw terminal for J9 and optional keyboard connection (2)
2
121108
Label, Terminal Block Identification (1)
1
Table 2-1. Parts Kits Contents (PN 121143)
A
B
Detail A
Detail B
Inside Enclosure
To Terminal
Block R
To Relay
Board
J4-8
To CPU Board
J2-2
J2-5
J2-6
J2-4
Wires To CPU Board
J2-3
CPU Board
Wires to Relay Board
J4-1
J4-3
J4-5
J4-7
Relay
Board