Rice Lake 920i FlexWeigh Systems - 201/202 User Manual

Page 13

Advertising
background image

Installation

9

Digital I/O

Table 2-3. Digital I/O Assignments

Slot

Bit

Type

Function

0

1

Programmability

E-Stop

0

2

Programmability

Start

0

3

Programmability

Resume

0

4

Programmability

Reset

0

5

Programmability

Ok to Discharge

0

6

Off

Currently Not Used

2

1

Output

Zero Tolerance

2

2

Output

Fill Complete

2

3

Output

Discharge

2

4

Output

Currently Not Used

2

5

Output

Ingredient #1

2

6

Output

Ingredient #2

2

7

Output

Ingredient #3

2

8

Output

Ingredient #4

2

9

Output

Ingredient #5

2

10

Output

Ingredient #6

2

11

Output

Ingredient #7

2

12

Output

Ingredient #8

2

13-24

Off

Currently Not Used

Serial Ports

Table 2-4. Serial Port Setup

Port

Type

Description

Setup

1

CMD

Currently not used

9600 baud
8 bit
None
2

2

CMD/KEYBOARD

iRev downloads/operator input

115200
8 bit
None
2

3

CMD

Audit trail printer

9600 baud
8 bit
None
2

4

CMD

Currently not used

9600 baud
8 bit
None
2

Advertising