2 add/edit formulas, 3 delete formulas, 4 exit – Rice Lake 920i FlexWeigh Systems - 201/202 User Manual

Page 22: 11 delay after discharge, Add/edit formulas, Delete formulas, Exit, See section 3.11

Advertising
background image

18

System 201/202 Basic Filler

5. The system prompts

Enter Ingredient Name

. Enter the name and press

Enter

.

6. The system prompts

Enter Ingredient Preact

. Enter a value and press

Enter

.

Note

Note

Preact weight allows material to cut off prior to the original target value to allow for free fall material to settle
onto the scale.

Prior to entering new value, the existing value needs to be cleared by using the clear key.

7. Press

Enter

to save.

8. Press

Exit

to return to previous menu.

To enter alpha characters, press the Up Arrow to access a pop up an alphabetic screen. Use arrows to select
letters.

Use keypad to enter numeric values.

3.10.2 Add/Edit Formulas

1. From the main setup menu screen, press

More=>

to access the next menu screen (shown in Figure 3-5).

2. Press

Database Setup

.

3. Press

Add/Edit Formulas

.

4. The system prompts

Enter Formula ID

. Enter the ID and press

Enter

.

5. The system prompts

Enter Formula Name

. Enter the name and press

Enter

.

6. The system prompts

Enter Ingredient ID

. Enter a value and press

Enter

.

7. The system prompts

Enter Ingredient Target Weight

. Enter a value and press

Enter.

Note

Note

Target weight is the desired weight value for a final fill weight.

Prior to entering new value, the existing value needs to be cleared by using the clear key.

8. The system prompts

Enter Ingredient Dribble Weight

. Enter a value and press

Enter.

When a 2-speed fill is enabled (either Parallel or Sequential), Dribble Weight is the desired weight value below
the Target Weight that the cycle switches from Fast Feed to Dribble Feed.

Prior to entering new value, the existing value needs to be cleared by using the clear key.

9. The system prompts

Enter Ingredient Order

. Enter a value and press

Enter

.

10. The system prompts

More Ingredients.

Press

Yes

to add more ingredients or

No

to save and exit.

3.10.3 Delete Formulas

Removes selected formula from the database.

1. Press

Delete Formulas

.

2. Enter Formula ID, then press

Enter

to delete.

3.10.4 Exit

Press the

Exit

to return to previous menu.

3.11 Delay After Discharge

The delay allowed after discharge is complete before beginning a new batch. This allows the discharge gate to
close before new batch begins loading.

1. From the main setup screen, press

More =>

twice to access the third setup menu screen.

2. Press

Delay After Disch.

Advertising