13 zero tolerance weight, 14 modifying the discharge option, E section 3.13 – Rice Lake 920i FlexWeigh Systems - 201/202 User Manual

Page 24

Advertising
background image

20

System 201/202 Basic Filler

3.13 Zero Tolerance Weight

The weight under which the system considers the scale to be empty and allow a new batch to begin.

Note

If a password is in the system, see Section 3.4 to enter the setup menu.

Prior to entering a new value, the existing value needs to first be cleared by using the clear key.

1. From the main setup menu screen, press

More=>

twice to access the third menu screen.

2. Press

Zero Toler Weight

.

Enter Zero Tolerance Weight
=> 110.00

08/27/2012

02:15PM

SCALE #1

000.0

SCALE

#1

Gross
Lb

Target

Dribble

Preact

Ingredient Name

0.50 lb

0.00 lb

0.04 lb

Ingredient 1

Consecutive Nbr

Near Zero

Formula Name

Batch Total

9

0.04 lb

Grout

0.00 lb

Home

Exit

Cancel

Figure 3-14. Enter Zero Tolerance Weight

3. Enter the zero tolerance weight using the numeric keypad.

4. Press

Enter

save value.

3.14 Modifying the Discharge Option

Note

If a password is in the system, see Section 3.4 to enter the setup menu.

Prior to entering a new value, the existing value needs to first be cleared by using the clear key.

1. From the main setup menu screen, press

More=>

four times to access the next menu screen.

2. Press

Discharge Option

.

3. Press

Discharge Enabled

or

Discharge Disabled

. System will toggle between the two modes of operation:

- Enabled: 920i System 202, system controlled discharge at batch complete.
- Disabled: 920i System 201, External provided method to empty scale at batch complete.