3 front panel configuration, 4 setting numeric values for parameters, Front panel configuration – Rice Lake Tracer AV User Manual

Page 15: Setting numeric values for parameters, Press

Advertising
background image

Tracer AV Installation Manual - Configuration

11

3.1.3

Front Panel Configuration

The

Tracer AV

can be configured using a series of menus viewed on the RD-1 display when the

Tracer AV

is in

setup mode. Table 3-1 summarizes the functions of each of the main menus.

The two-button numeric editor works as follows:

Press

Units

to navigate RIGHT. Press

Zero

to drop DOWN or select from a list of values.

Figure 3-2. Setup Mode Menu Navigation

3.1.4

Setting Numeric Values For Parameters

1. Press

Zero

to immediately accept the current value and navigate to the next menu item.

2. Press

Units

to enter edit mode.

The leftmost digit will flash to indicate it can be altered.

3. Press

Zero

to increment to the desired value.

4. When the value is correct, press

Units

to move to the next digit.

Menu

Menu Function

DEFCAL

Default
Configuration

Select a 500lb or 300lb default configuration. You can also display and edit zero calibration a/d
count value, test weight value, and span calibration a/d count value.

CONFIG

Configuration

Configure grads, zero tracking, zero range, motion band, overload, tare function, sample rate,
and digital filtering parameters.

FORMAT

Format

Set format of primary and secondary units, display rate.

CALIBR

Calibration

Calibrate

Tracer AV

. See Section 4.0 on page 23 for calibration procedures.

SERIAL

Serial

Configure EDP and printer serial ports.

PROGRM

Program

Set power-up mode, regulatory mode, and consecutive number values.

SETPNT

Setpoint

Configure Setpoints and digital outputs.

VERS

Version

Display installed software version number.

Table 3-1.

Tracer AV Menu Summary

Button

Function

Zero

Move DOWN/ Increment Value

Units

Move RIGHT/Next

Table 3-2. Button Functions in Setup Mode

1

st

Level

Parameter

Default value

Value

1

st

Level

Parameter

2

nd

Level

Parameter

2

nd

Level

Parameter

Value

Value

When moving through values below the first menu, press UNITS to view the
selections. Press ZERO to set the parameter and move to the next parameter on the
leval above.