6.10 Specifications

Power

Line Voltages

115 or 230 VAC

Frequency

50 or 60 Hz

Power Consumption

1.5 A @ 115 VAC (8W)
0.75 A @ 230 VAC (8W)

Fusing

2.5 A 5 x 20 mm fuse

Analog Specifications

Full Scale Input Signal Up to 22.5 mV
Excitation Voltage

+5V single sided
8 x 350

 or 16 x 700 load cells

Sense Amplifier

Differential amplifier with
4- and 6-wire sensing

Analog Signal

Input Range

–0.5 mV/V to +4.5 mV/V

Analog Signal

Sensitivity

0.3

V/graduation minimum,

1.5

V/grad recommended

Input Impedance

200 M

, typical

Noise (ref to input)

0.3

V p-p with digital filters at 4-4-4

Internal Resolution

8,000,000 counts

Display Resolution

100 000 dd

Measurement Rate

Up to 60 measurements/sec

Input Sensitivity

10 nV per internal count

System Linearity

Within 0.01% of full scale

Zero Stability

150 nV/°C, maximum

Span Stability

3.5 ppm/°C, maximum

Calibration Method

Software, constants stored in
EEPROM

Common Mode

Voltage

–2.35 to +3.45 V, referred to ground

Rejection

130 dB minimum @ 50 or 60 Hz

Normal Mode

Rejection

90 dB minimum @ 50 or 60 Hz

Input Overload

± 12 V continuous, static discharge
protected

RFI Protection

Signal, excitation, and sense lines
protected by capacitor bypass

Analog Output

Optional: fully isolated, voltage or
current output,14-bit resolution.
Voltage output: 0 –10 VDC
Load resistance:1K

 minimum

Current output: 0–20/4–20 mA
External loop resistance: 500

maximum

Digital Specifications

Microcomputer

Phillips PXAG30K main processor @
19.6608 MHz

Digital Inputs

2 inputs, TTL or switch closure,
active-low

Digital Outputs

2 outputs, 250 mA Max Sink

Digital Filters

3 filters, software selectable

Serial Communications

EDP Port

Full duplex RS-232

Printer Port

Full duplex RS-232 or active transmit
only 20 mA current loop

Both Ports

38400, 19200, 9600, 4800, 2400,
1200, 600, 300 bps; 7 or 8 data bits;
even, odd, or no parity

Operator Interface

Display

6-digit LED display. 7-segment, 1.8 in
(44.5 mm) digits

LED annunciators

Gross, net, center of zero, standstill,
lb/primary units, kg/secondary units,
count, tare

Keypad

2-button keypad

Environmental

Operating Temperature –10 to +40°C (legal);

–10 to +50°C (industrial)

Storage Temperature

–25 to +70°C

Humidity

0–95% relative humidity

Enclosure

Enclosure Dimensions 10.5 in x 12.5 in x 6.4 in

26.7 cm x 31.75 cm x 16.3 cm

Weight

7.8 lb. (3.54 Kg)

Rating/Material

UL Type 1

Advertising