7 setpoint menu, Setpoint menu – Rice Lake Tracer AV User Manual

Page 25

Advertising
background image

Tracer AV Installation Manual - Configuration

21

3.2.7

Setpoint Menu

Figure 3-10. Setpoint Menu

Table 3-9. Setpoint Menu Parameters

GROSS

NET

SETPT1

Same as SETPT1

XXXXXXX

XXXXXXX

PROGRM

SERIAL

CALIBR

CONFIG FORMAT

XXXXXXX

SETPNT

KIND

number

V ALUE

HIGHER

LOWER

TRIP

number

BNDVAL

INBAND

OUTBAND

number

HYSTER

OFF

ON

ENABLE

OFF

ON

ACCESS

If TRIP = HIGHER/

LOWER

SETPT2

VERS

DEFCAL

SETPNT Menu

Parameter

Choices

Description

Level 2 submenus

SETPT1
SETPT2

ENABLE
KIND
VALUE
TRIP
BNDVAL

Specifies settings for setpoint enable, kind, weight value, trip, and band value used by the
setpoint

Level 3 submenus

ENABLE

OFF
ON

Turns setpoint ON or OFF.

KIND

GROSS
NET

Specifies the setpoint kind and determines whether function is based on GROSS or NET
weight.

GROSS or NET setpoint kinds can be used.

VALUE

number

Displays and edits the setpoint value

TRIP

HIGHER
LOWER
INBAND
OUTBND

Trips the setpoint when the weight is higher or lower than the setpoint value, or is within or
outside of the band value. LOWER means the output is active until you reach weight. If trip is
HIGHER, the output is active when the setpoint is met or exceeded. INBAND means the
output is active if the weight is within the band value. If trip is OUTBND, the output is active
when the weight is outside of the band value.

BNDVAL

number

The band value for either INBAND or OUTBND trip setpoints. BNDVAL is ignored unless trip is
set to INBAND or OUTBND.

HYSTER

number

Specifies a band around the setpoint value that must be exceeded before the setpoint, once
off, can trip on. If TRIP = HiGHER or LOWER.

ACCESS

OFF
ON

Front panel access to setpoints. Specify OFF if setpoints will not be used. ON enables
operator to turn setpoints on/off, change value, or change BANDVAL via front panel entry
during weigh mode.