Tracer AV Installation Manual - EDP Commands

27

5.1.2

Reporting Commands

Reporting commands (see Table 5-2) send specific
information to the EDP port. These commands can be
used in both setup mode and normal mode.

5.1.3

The RESETCONFIGURATION Command

The

RESETCONFIGURATION

command can be used to

restore all configuration parameters to their default
values. Before issuing this command, the

Tracer AV

must be placed in test mode (press and hold setup
switch for approximately three seconds to show TEST
menu).

This command is equivalent to using the DEFLT
function on the TEST menu. See Section 6.7 on
page 39 for more information about test mode and
using the TEST menu.

NOTE: All load cell calibration settings are lost when the
RESETCONFIGURATION command is run.

5.1.4

Parameter Setting Commands

Parameter setting commands allow you to display or
change the current value for a particular configuration
parameter (Tables 5-3 through 5-11).

Current configuration parameter settings can be
displayed in either setup mode or normal mode using
the following syntax:

command<ENTER>

Most parameter values can be changed in setup mode
only. Use the following command syntax when
changing parameter values:

command=value<ENTER>

where

value

is a number or a parameter value. Use no

spaces before or after the equal (=) sign. If you type an
incorrect command or value, the display reads

??

.

Changes to the parameters are saved as they are
entered but typically do not take effect until you exit
setup mode.

For example, to set the motion band parameter to 5,
type the following:

MOTBAND=5D<ENTER>

5.1.5

Soft Reset

The

RS

command will reset the

Tracer AV

without

losing configuration and calibration. It does reset
consecutive number.

Command

Function

DUMPALL

List all parameter values

VERSION

Tracer AV

software version

P

Write current displayed weight with units
identifier. See Section 6.2 on page 33 for
more information.

ZZ

Write current weight and annunciator
status. See Section 6.2 on page 33 for
more information.

S

Write one frame of stream format. See
Table 5-12 on page 30 for information
about the SX and EX commands.

Table 5-2. EDP Reporting Commands

Command

Description

Values

DEFCAL

Default Calibration

300lb, 500lb

GRADS

Graduations

1–100 000

ZTRKBND

Zero track band

OFF, 0.5D, 1D, 3D

ZRANGE

Zero range

1.9%, 100%

MOTBAND

Motion band

1D, 2D, 3D, 5D, 10D, 20D, OFF

OVRLOAD

Overload

FS+2%, FS+1D, FS+9D, FS

SMPRAT

Sample rate

15HZ, 30HZ, 60HZ, 7.5HZ

DIGFLTR1
DIGFLTR2
DIGFLTR3

Digital filtering

1, 2, 4, 8, 16, 32, 64

DFSENS

Digital filter cutout sensitivity

2OUT, 4OUT, 8OUT, 16OUT, 32OUT, 64OUT, 128OUT

DFTHRH

Digital filter cutout threshold

NONE, 2DD, 5DD, 10DD, 20DD, 50DD, 100DD, 200DD, 250DD

TAREFN

Tare function

BOTH, NOTARE, PBTARE, KEYED

Table 5-3. CONFIG EDP Commands