Press the, Softkey – Rice Lake BCi Belt Scale - Calibration Guide User Manual

Page 10

Advertising
background image

6

BCi In-Motion Belt Scale System

3. Press the

Start

softkey.

Exit=>

SCALE #1

Start

5/30/2013

08:19AM

Admin. Passcode (numeric)

Scale Capacity (Max Rate)

Load Cell MV

Total LC Build

Rate Unit Time

Filter (s)

Filter Threshold (divisions)

Speed Unit Time

Fixed Speed

Unit of Measure

420.00

1.99900

800

hr
7.0

2

min

0.00

ft

Figure 3-8. Start Softkey

The Zero Cal test will run, and will show a progress screen, Figure 3-9.

5/30/2013

09:16AM

Exit =>

Start

SCALE #1

Progress

Test Time

Test Accumulator

Old Zero Error %

Zero Error %

6.2

0.3

-0.03

Figure 3-9. Zero Cal Test Running

After the test is completed the new zero error % will be shown on the display.

5/30/2013

09:17AM

No

Yes

SCALE #1

Progress

Test Time

Test Accumulator

Old Zero Error %

Zero Error %

6.2

66.7

38.58

Accept New Zero

0.00%

Figure 3-10. Zero Error % Complete

Advertising