Press the, Softkey – Rice Lake BCi Belt Scale - Calibration Guide User Manual
Page 10
6
BCi In-Motion Belt Scale System
3. Press the
Start
softkey.
Exit=>
SCALE #1
Start
5/30/2013
08:19AM
Admin. Passcode (numeric)
Scale Capacity (Max Rate)
Load Cell MV
Total LC Build
Rate Unit Time
Filter (s)
Filter Threshold (divisions)
Speed Unit Time
Fixed Speed
Unit of Measure
420.00
1.99900
800
hr
7.0
2
min
0.00
ft
Figure 3-8. Start Softkey
The Zero Cal test will run, and will show a progress screen, Figure 3-9.
5/30/2013
09:16AM
Exit =>
Start
SCALE #1
Progress
Test Time
Test Accumulator
Old Zero Error %
Zero Error %
6.2
0.3
-0.03
Figure 3-9. Zero Cal Test Running
After the test is completed the new zero error % will be shown on the display.
5/30/2013
09:17AM
No
Yes
SCALE #1
Progress
Test Time
Test Accumulator
Old Zero Error %
Zero Error %
6.2
66.7
38.58
Accept New Zero
0.00%
Figure 3-10. Zero Error % Complete