Auto cal, 2 auto cal, A. test weight procedure – Rice Lake BCi Belt Scale - Calibration Guide User Manual

Page 11: Press, Press the, Softkey to move on to auto cal, Softkey

Advertising
background image

Calibration

7

4. Press

Yes

to accept the value. Repeat the zero cal until the zero percent error is very near to zero error

percent

5/30/2013

09:17AM

Exit=>

Start

SCALE #1

Progress

Test Time

Test Accumulator

Old Zero Error %

Zero Error %

6.2

66.7

38.58

0.00%

Figure 3-11. Exit Zero Cal

5. Press the

Exit

softkey to exit back to the integrator weigh screen.

3.2.2

Auto Cal

Press the

Auto Cal

softkey to move on to Auto Cal.

Exit=>

SCALE #1

Auto Cal

5/30/2013

08:18AM

Admin. Passcode (numeric)

Scale Capacity (Max Rate)

Load Cell MV

Total LC Build

Rate Unit Time

Filter (s)

Filter Threshold (divisions)

Speed Unit Time

Fixed Speed

Unit of Measure

420.00

1.99900

800

hr
7.0

2

min

0.00

ft

Zero Cal

Material

Figure 3-12. Enter Auto Cal

A. Test Weight Procedure

1. Place a known weight on the weight hangers.

2. Press the

Test Weights

softkey.

5/30/2013

09:17AM

Exit =>

Test

Weights

SCALE #1

Progress

Test Time

Test Accumulator

Old Span Error %

Span Error %

6.2

0.0

2.55

0.00%

Test Chain

Figure 3-13. Test Weights Procedure

Advertising