Auto cal, 2 auto cal, A. test weight procedure – Rice Lake BCi Belt Scale - Calibration Guide User Manual
Page 11: Press, Press the, Softkey to move on to auto cal, Softkey
Calibration
7
4. Press
Yes
to accept the value. Repeat the zero cal until the zero percent error is very near to zero error
percent
5/30/2013
09:17AM
Exit=>
Start
SCALE #1
Progress
Test Time
Test Accumulator
Old Zero Error %
Zero Error %
6.2
66.7
38.58
0.00%
Figure 3-11. Exit Zero Cal
5. Press the
Exit
softkey to exit back to the integrator weigh screen.
3.2.2
Auto Cal
Press the
Auto Cal
softkey to move on to Auto Cal.
Exit=>
SCALE #1
Auto Cal
5/30/2013
08:18AM
Admin. Passcode (numeric)
Scale Capacity (Max Rate)
Load Cell MV
Total LC Build
Rate Unit Time
Filter (s)
Filter Threshold (divisions)
Speed Unit Time
Fixed Speed
Unit of Measure
420.00
1.99900
800
hr
7.0
2
min
0.00
ft
Zero Cal
Material
Figure 3-12. Enter Auto Cal
A. Test Weight Procedure
1. Place a known weight on the weight hangers.
2. Press the
Test Weights
softkey.
5/30/2013
09:17AM
Exit =>
Test
Weights
SCALE #1
Progress
Test Time
Test Accumulator
Old Span Error %
Span Error %
6.2
0.0
2.55
0.00%
Test Chain
Figure 3-13. Test Weights Procedure