B. test chain procedure, Softkey, Press the – Rice Lake BCi Belt Scale - Calibration Guide User Manual

Page 13

Advertising
background image

Calibration

9

B. Test Chain Procedure

10. Place test chain on conveyor, spanning over the weighing area.

11. Press the

Test Chain

softkey.

5/30/2013

09:17AM

Exit =>

Test

Weights

SCALE #1

Progress

Test Time

Test Accumulator

Old Span Error %

Span Error %

6.2

0.0

2.55

0.00%

Test Chain

Figure 3-17. Test Chain Procedure

12. Press the

Start

softkey

5/30/2013

09:18AM

Exit =>

Start

SCALE #1

Progress

Test Time

Test Accumulator

Old Span Error %

Span Error %

6.2

0.00

2.55

0.00%

Figure 3-18. Start Test Chain Procedure

The Auto Cal test will run, and will show a progress screen. A prompt to enter a test chain value will
display. The test chain value is noted in lb/ft.

5/30/2013

09:35AM

End

Home

SCALE #1

Progress

Test Time

Test Accumulator

Old Span Error %

Span Error %

18.8

62

0.00

Enter Test Chain Value
=> 10.0

Cancel

Figure 3-19. Enter Test Chain Value

13. Press the

CLR

key on the integrator to clear off the current value, enter a new test chain value using the

numeric keypad.

14. Press the

enter

key on the integrator to accept the next test chain value. After the test chain value is entered,

the new span error is displayed.

Advertising