B. test chain procedure, Softkey, Press the – Rice Lake BCi Belt Scale - Calibration Guide User Manual
Page 13
Calibration
9
B. Test Chain Procedure
10. Place test chain on conveyor, spanning over the weighing area.
11. Press the
Test Chain
softkey.
5/30/2013
09:17AM
Exit =>
Test
Weights
SCALE #1
Progress
Test Time
Test Accumulator
Old Span Error %
Span Error %
6.2
0.0
2.55
0.00%
Test Chain
Figure 3-17. Test Chain Procedure
12. Press the
Start
softkey
5/30/2013
09:18AM
Exit =>
Start
SCALE #1
Progress
Test Time
Test Accumulator
Old Span Error %
Span Error %
6.2
0.00
2.55
0.00%
Figure 3-18. Start Test Chain Procedure
The Auto Cal test will run, and will show a progress screen. A prompt to enter a test chain value will
display. The test chain value is noted in lb/ft.
5/30/2013
09:35AM
End
Home
SCALE #1
Progress
Test Time
Test Accumulator
Old Span Error %
Span Error %
18.8
62
0.00
Enter Test Chain Value
=> 10.0
Cancel
Figure 3-19. Enter Test Chain Value
13. Press the
CLR
key on the integrator to clear off the current value, enter a new test chain value using the
numeric keypad.
14. Press the
enter
key on the integrator to accept the next test chain value. After the test chain value is entered,
the new span error is displayed.