Press the, Softkey – Rice Lake BCi Belt Scale - Calibration Guide User Manual
Page 12
8
BCi In-Motion Belt Scale System
3. Press the
Start
softkey
5/30/2013
09:18AM
Exit =>
Start
SCALE #1
Progress
Test Time
Test Accumulator
Old Span Error %
Span Error %
6.2
0.00
2.55
0.00%
Figure 3-14. Start Auto Cal with Test Weights
4. The Auto Cal test will run, and progress is shown on the screen. A prompt to enter a test weight value will
display.
5/30/2013
09:35AM
End
Home
SCALE #1
Progress
Test Time
Test Accumulator
Old Span Error %
Span Error %
18.8
62
0.00
Enter Test Weight Value
=> 10.0
Cancel
Figure 3-15. Enter Test Weight Value
5. Press the
CLR
key on the integrator to clear off the current value, enter a new test weight value using the
numeric keypad.
6. Press the
enter
key on the integrator to accept the next test weight value. After the test the test weight value
is entered, the new span error is displayed.
7. Press the
Yes
softkey to accept that value.
8. Repeat the test until the new span percent error is very near zero and then accept the new span value by
pressing the
Yes
softkey.
5/30/2013
09:32AM
No
Yes
SCALE #1
Progress
Test Time
Test Accumulator
Old Span Error %
Span Error %
18.8
62
95.00
0.10
Accept New Span Value
Figure 3-16. Accept Span Value
9. Press the
Exit
softkey to exit back to the integrator weigh screen.