2 weighing module, 1 types, 2 technical specifications – Rice Lake Contego-Hygienic Weigh Module Kits, Lateral Cable Outlet User Manual

Page 10: Weighing module, Types, Technical specifications

Advertising
background image

Hygienic Weighing Module Contego®

Installation Manual

EN-8

Sartorius

3.2

Weighing Module

3.2.1

Types

3.2.1.1

Weighing Module Incl. Load Cell

For nominal load E

max

Error class

Type*

100 kg

D1

A, Ex A, B, Ex B

200 kg

D1, C3

A, Ex A, B, Ex B

300 kg

D1, C3

A, Ex A, B, Ex B

500 kg

D1, C3

A, Ex A, B, Ex B

1 t

D1, C3

A, Ex A, B, Ex B

2 t

D1, C3

A, Ex A, B, Ex B

* A = cable outlet on side

B = cable outlet on top
Ex = for installation in the explosion-hazarded area

3.2.1.2

Weighing Module without Load Cell (Service)

PR 6041/60S

Mounting kit with cable outlet on side

PR 6041/70S

Mounting kit with cable outlet on top

3.2.2

Technical Specifications

Permissible horizontal force

7 kN

Permissible vertical load without load cell

1.5 t

Permissible lift-off force

8 kN

Permissible force for jack-up

15 kN

Permissible temperature range

-40 °C to +95 °C

Protection classes


Dust and water


IP69K:
Protection against dust
as per DIN EN 60529 09/2000 Paragraph 13.4
Protection against water (high-pressure cleaning)
as per DIN 40050 Part 9

Explosion

Suitable for sub-groups IIA, IIB, and III for explosive
atmospheres. Please ask regarding IIC compliance.

Material

Bellow

Silicone (FDA-compliant)

Mounting kit

1.4404 (AISI 316L)

Weight of
cpl. weighing module

net

approx. 11 kg

gross

approx. 12 kg