12 Equipoise Series Technical Manual
Table 5-1. Parameter Settings
Menu
Sub Menu
Description
F1 unt
g / ct / lb / oz / d / gn / ozt /
dwt / mm / tl.T / tl.c / tl.t / t,.
To set units, each one can be set to on or
off.
F2 el
El au
On
When weight is on the pan the backlight
will turn on.
Off
El on
On
Backlight is always on when balance is
turned on.
Off
El off
On
Backlight is always off when balance is
turned on.
Off
F3 com
P prt
By pressing Print key , weighing value will
be added to the memory and send to
printer if connected.
P cont
Sends data continuous.
P auto
Automatic accumulation.
Individual weighing values are automatically
added
Set BAUD rate
After setting the RS 232 mode, display will be shown current baud rate b
XXX.
Baud rate Options: b600, b1200, b2400, b4800 and b9600
Set Printer type
After setting BAUD rate display will be show the printer type
Lp 50
Not Available
Tp
Ticket Printer
F4 ACC
ACC ON
Turn on accumulation
ACC OF
Turn off accumulation
tech
pin
Factory Access Only
P 1 lin
Linear Calibration
P 2 Cal
Normal Calibration
P 3 cnt
xxxx
This display will show XXXXX for indicating
the internal counts
P 4 a 2n
0 .5 d
To set auto zero
1 d
2 d
4 d
P 5 gra
Xxxx
To set local gravity