Rice Lake Equipoise Series, Rice Lake Weighing Systems User Manual

Page 19

Advertising
background image

Error Codes 15

Err 8

External calibration weight error

More than 4% error as linear
calibration

Err 9

Unstable, can’t perform zero or tare

Err 10

No data

RS-232, continous
communication

Err 11

Won’t accept communication protocal

Can get signal but can’t support

Err 12

Accumulation error

Max accmulate time 999 or total
weight 999999 has been
reached.

Err 13

Lack of unit weight

Counting: unit weight < 0.5d

Err 14

Lack of sample

Counting: sample weight < 20d

Err 15

Error gravity value setting

Gravity value range 0.96-1.04

Err 16

No paper

Err 17

Tare Operation

Minus weight or overload

Err 18

Incorrect pre-tare operation

Minus weight or overload

Err P

Printer no response 2 seconds later

OK

Set password OK

PASS

Calibration OK

Fail

Calibrate or password setting fail

NG

RS-232 Command error

--OL-

Overload

Max +9d (NTEP: 105% capacity)

--LO-

Minus weight

-5% capacity

Bat lo

Battery voltage too low

<5.9v

Measuring Points

Resistance

Red (+ Exc) to White ( –Exc)

420 ±20Ω

Green (+Sig) to Black ( –Sig)

350Ω ±5Ω

Error

Code

Description

POSSIBLE CAUSES

Table 7-1. Error Codes