Calibration switch, How to calibrate the scale – Rice Lake Intercomp CS 750 - Users Manual User Manual

Page 13

Advertising
background image

CS750, Users

Rev R, May 2009

Page 13 of 27

Calibration switch

The calibration of the scale is protected from accidental change by a switch just inside
the right side panel.

Enabling the Calibration switch

Using a screwdriver, remove the right side plate and move the switch to “CAL”.
When you are done calibrating, return the switch to “RUN” to protect against
change.

How to calibrate the scale

The following details the calibration procedure for the crane scale. There are eight
parameters that can be set without moving the calibration blocking switch, followed by
five more parameters and calibration that require the calibration blocking switch be in
the enabled position.

Display Parameter

Note

Default

ee-ee

ee-ee

ee-ee

ee-ee Skip

0=no skip, 1=”EE-10

EE-10

EE-10

EE-10”, 2=”LL-00

LL-00

LL-00

LL-00”

0

EE-00

EE-00

EE-00

EE-00 Sample Rate

1 to 64

4

EE-01

EE-01

EE-01

EE-01 Update Rate

1 to 32

4

EE-02

EE-02

EE-02

EE-02 Demand Output

1=Continuous off
0=Continuous on

0

EE-03

EE-03

EE-03

EE-03 Baud Rate

0 to 9

0

EE-04

EE-04

EE-04

EE-04 Auto-off Time

0 to 255; 0=off

20

EE-05

EE-05

EE-05

EE-05 Power up in KG

1=kg, 0=lb

0

EE-06

EE-06

EE-06

EE-06 Not Used

Not Used

0

EE-07

EE-07

EE-07

EE-07 Sleep Mode Time

0 to 255; 0=off

5

ee-08

ee-08

ee-08

ee-08 Set Point 1

1 to 99999

99999

ee-09

ee-09

ee-09

ee-09 Set Point 2

1 to 99999

99999

Information saved

Check for calibration
blocking switch

EE-10

EE-10

EE-10

EE-10 AZT

0=off,1=0.6,2=1,3=3

2

EE-11

EE-11

EE-11

EE-11 Zero Range

0=off,1=on

0

EE-12

EE-12

EE-12

EE-12 Canadian Specifications 0=off, 1=on

0

EE-13

EE-13

EE-13

EE-13 Initial Zero Range

0=off, 1=on

0

EE-14

EE-14

EE-14

EE-14 Graduation

0 to 11

6

Information saved

LL-00

LL-00

LL-00

LL-00 Zero read

Enter capacity

LL-01

LL-01

LL-01

LL-01 First weight

Enter first weight

LL-02

LL-02

LL-02

LL-02 Second weight

Enter second weight

LL-03

LL-03

LL-03

LL-03 Third weight

Enter third weight

Information saved

Advertising