Error messages – Rice Lake Intercomp CS 750 - Users Manual User Manual

Page 21

Advertising
background image

CS750, Users

Rev R, May 2009

Page 21 of 27

Error Messages


[Minus signs cycle across the display]: The CS750 has entered sleep mode.
Press any key or change the weight to return to normal weighing.
NOTE: a pressed key here will perform its designated function as well as exit the scale
from sleep mode.

[Minus signs fill the display]: The CS750 is waiting for a stable reading to continue.

LB

LB

LB

LB

Low batteries. This message blinks, and if ignored too long the unit will
shut itself off.

OE

OE

OE

OE

The scale is over capacity or outside the A/D converter range. Reduce the
load to the scale.

DISE

DISE

DISE

DISE

Display error, the scale is unable to display the number completely. Press
zero to return the weight reading to zero.

EEPE

EEPE

EEPE

EEPE

EEPROM error, the scale has had it's calibration corrupted or destroyed;
the scale will require calibration.

OL

OL

OL

OL

Zero overload; the CS750 has attempted to zero a reading outside of its
zero-range limit. This message can occur only when the “Zero range” or
“Canadian specifications” is turned on. See “EE-11

EE-11

EE-11

EE-11” and “EE-12

EE-12

EE-12

EE-12” in the

“calibration” section.

E-0

E-0

E-0

E-0

This message occurs if the scale is turned on with a load applied which is
greater than +/- 10% of capacity. Return the scale's load to zero. This only
occurs when “Canadian specifications” or “Initial zero range” is turned on.
See “EE-12

EE-12

EE-12

EE-12” and “EE-13

EE-13

EE-13

EE-13” in the “calibration” section.


Advertising