Operation, Power/batteries, Periodic maintenance – Rice Lake Intercomp CS 750 - Users Manual User Manual

Page 9: Replacement, Rechargeable (ni-cad)

Advertising
background image

CS750, Users

Rev R, May 2009

Page 9 of 27

Operation

Use

Periodic Maintenance

Power/Batteries

Replacement

On the right side panel, remove the two screws that hold the back plate secure.
Slide this plate out to access the batteries inside. Change the cells, being
careful to note battery orientation.

You may use 6 rechargeable Nickel-Cadmium “D” cells or 6 standard “D” cells in
the CS750.

Warning: Do not plug the charger in while there are standard “D”
cells inside. This could result in damage to the batteries and your

scale.

Rechargeable (Ni-cad)

The typical recharge time for Ni-Cad cells is 16 hours. The rechargeable
batteries have a life span up to 1000 cycles.