Introduction


This manual contains specifications, operation instructions, and calibration instructions
for Intercomp's model CS750 crane scale.

Specifications

Controls

General:

Zero, On, Off, Backlight

Display:

5 digit LCD.

Indicators: lb, kg.

Electrical

Batteries:

6 X D-size disposable alkaline dry cells or rechargeable Nickel-
Cadmium cells.

Battery life:

Up to 250 hours with alkaline batteries. Approximately 80 hours
on a set of fully charged Ni-Cad cells.

Resolution:

20 bit A/D delivers over 1,000,000 internal counts.

Filtering:

6 Pole, 10 Hertz low pass.

Auto off:

Low battery, or after adjustable time without use or motion.

Sleep
mode:

Display sleep mode after adjustable time without use or motion.

Auto-Zero:

Satisfies all HB-44 requirements; selectable 0.6, 1, or 3
graduations.

Performance

Accuracy: ±0.1% of applied load or ± display graduation, whichever is greater.


Environmental

Humidity:

10 to 95% Non-Condensing

Temperature:

Storage: -40 C to +75 C. / -40 F to +170 F.

Operating -10 C to +50 C. / +14 F to +122 F.


Physical

Dimensions:

Control Box:

4.25" x 5" x 8.5". / 10.8 cm X
12.7 cm x 21.6 cm.

Lifting eye to hook (Standard):

12" / 30.5 cm.

Weight:

7.5 lb. / 3.4 kg.