Rice Lake MSI-8000 RF Remote Display User Manual

Page 18

Advertising
background image

1)

Program a function key to Peak
Hold (P-Hld)

In this example we’ll use

F1

for Peak

Hold.

2)

Prepare the test stand and test
sample.

3)

Press

ZERO

to zero out any

residual strain on the link.

4)

Press

F1 PkHold

Confirm that

the “Pk” annunciator is on.

A small jump in the reading may occur
depending on the stability of your test
stand.

5)

Apply the test force. The F1 LED
will blink three times for every
new peak it detects.

6)

When the test force is removed,
the Peak value can be recorded.

7)

To run a new test, press

F1 PkHold

to clear the Peak

Value. Confirm the “Pk”
annunciator is off. Then repeat
steps 3-6.

Peak Hold

kg

lb

M

kN

Ton



kg

lb

M

kN

Ton

Pk

kg

lb

M

kN

Ton



kg

lb

M

kN

Ton

Pk

Example Peak Captured Value

Peak Hold

kg

lb

M

kN

Ton



kg

lb

M

kN

Ton

kg

lb

M

kN

Ton



kg

lb

M

kN

Ton

Peak Cleared Value

Capture Peak Force

F1

F1

0

ZERO

See Function Key
Setup on Section 4.2

14

MSI-8000

Operator’s Manual

Figure 3-1. Capture Peak Force

2-Units/ 5-Units

The

Fx-2.Unit

key will switch the force units between pounds force and kilograms force.

Selecting the

Fx-5.Unit

setting will scroll through all available units: lb, kg, Tons (US

Short), Metric Tons, and kiloNewtons.