Rice Lake Scout Pro Series Portable, Ohaus - Service Manual User Manual

Page 12

Advertising
background image

2-2

CHAPTER 2 DIAGNOSIS

REMEDY

1. Check AC Adapter.

2. Replace Power Jack.

3. Replace.

4. Clean or replace.

5. Replace PC Board.

1. Replace battery.

2. Replace AC Adapter.

3. Replace PC Board.

1. Replace battery.

2. Replace PC Board.

1. Perform linearity calibra-

tion.

2. Set per specifications.

3. Plug in Transducer.

4. Replace Transducer.

5. Replace PC Board.

1. Use correct masses.

2. Plug in Transducer.

3. ReplaceTransducer.

4. Replace PC Board.

1. Put pan on balance
2. Check stops and reset if

necessary.
3. Perform factory calibra-

tion B.1 or B.2

TABLE 2-1. DIAGNOSTIC GUIDE

PROBABLE CAUSE

1. No power.

2. Power Jack defective.

3. Weak battery.

4. Battery connector - poor

contact.

5. PC Board defective.

1. Weak battery.

2. AC Adapter defective or

wrong type being used.

3. PC Board defective.

1. Weak battery.

2. PC Board defective.

1. Possible power surge.

2. Down stop improperly set.

3. Transducer not con-

nected.

4. Defective Transducer.

5. PC Board defective.

1. Incorrect calibration

masses.

2. Transducer not con-

nected.

3. Defective Transducer.

4. PC Board defective.

1. Missing Pan.
2. Down Stop improperly

set.

3. Transducer zero has shifted.

SYMPTOM

No display.

Low BAT displayed.

Stays in segment check.

Always displays zero.

Cannot calibrate.

Displays (Err2)