Step 4 – Empty de-scale Solution
The GRIND LCD will display 04 during

Step 4 procedure.

a)

Empty water tank, rinse and fill water

tank with clean water. Insert water tank

into machine.

b)

Rotate left screw first, counter-clockwise

until fully open. Water will begin to flow

into drip tray.

c)

Repeat with right screw. Steam will be

released from the boiler.

CAUTION HOT WATER

d)

Close valves when water stops flowing

through both outlets. Empty drip tray

and re-assemble onto unit.

CAUTION HOT STEAM

Step 5 – fill Boilers
The GRIND LCD will display 05 during

Step 5 procedure.
5 minute timer will begin. Wait for

countdown timer to get to 0:00.

(This allows any remaining solution

to be removed from system).

CArE & CLEAnIng

CArE & CLEAnIng

Step 6 – flush Boilers
The GRIND LCD will display 06 during

Step 6 procedure.

a)

Empty water tank, rinse and assemble

new water filter into tank.

b)

Fill water tank with clean water and

insert into machine.

c)

Rotate screws counter-clockwise, as per

previous instructions until fully open.

Water will begin to flow into drip tray.

d)

Close valves when water stops flowing

through both outlets. Empty drip tray

and re-assemble onto unit.

CAUTION HOT WATER

e)

Empty drip tray and re-insert

into machine.

f)

Push SELECT button to complete the

de-scale procedure. Machine will heat

up as normal.

SELECT

SELECT

SELECT