Quarterly, 4 quarterly – B&C Technologies SI Series Industrial User Manual

Page 49

Advertising
background image

the adjustement screw located on the inboard side of the pump. See figure 7.3 on page 46.
The hydraulic should fluid be changed every 2 years using hydraulic fluid type, HL, HM or
HV type and Viscosity Grade 22(VG22). To change the fluid disconnect the two hydraulic
hoses, the two DIN connectors, and four mounting screws. Remove pump and tank from
the machine and drain through the fill hole. Alternate method: remove fill cap and use hand
pump to drain fluid. Refill tank with approximately 3L of the recommended hydraulic fluid.

Figure 7.1: Hydraulic Pump Detail

7.4

Quarterly

NOTE: Disconnect power to the machine before performing the quarterly maintenance proce-
dures.

1. Tighten door hinges and fasteners, if necessary.

45

Advertising