Maintenance, Basic troubleshooting, Control problems – B&C Technologies IS Series Commercial Ironer User Manual

Page 31: Belt problems, Chapter 5 maintenance, 1 basic troubleshooting

Advertising
background image

Chapter 5

Maintenance

5.1

Basic Troubleshooting

5.1.1

Control Problems

Temperature Control shows S.Err

Indicates an input error. Check the input wiring for bad connections and short-circuits.

Temperature Control shows E111

Indicates a memory error. Turn the machine power off, then back on. If the display continues to
show the error, contact a qualified service technician.

Temperature Control shows cccc

Damaged sensor or wiring. Repair or replace.

Speed Display shows n1.Err, n2.Err, n3.Err, Err-o, or CHG-o

Indicates a memory error. Turn the machine power off, then back on. If the display continues to
show the error, contact a qualified service technician.

5.1.2

Belt Problems

The ironing belts will shrink under 3 conditions:

1. if they are installed with the wrong side to the heated cylinder (Gold side should face cylin-

der)

2. if they are taken off the machine when they are hot

3. if they are overheated by not spreading out small piece work across the cylinder