Tools needed:

• Slack Tube Manometer

• 1/8” pipe hose barb (for your manometer)

• 1/4” pipe hose barb (for your manometer)

• Volt Meter

Controls:

Refer to Figure 6.1 on page 33.

1. Gas Valve Pilot Coil

2. Gas Valve Main Coil

3. Pilot Gas Adjustment

4. Pilot Air Adjustment

5. Pilot Regulator

6. Main Air adjustment

7. Secondary Air Adjustment

8. Main Gas Cut-Off Valve

9. Shading Disk or Valve

10. Main Gas Pressure Test Port

11. Burner Pressure Switch

32