Service Functions

28

Access Functions continued

Function 223 continued
5. ENTER
The display now shows “COPY FROM
CARD?”
6. Press ENTER
The display now shows “COPY FROM CARD”
followed by “COPY OK.”

Disabling the Advance Key
Function 225
This function disables the ADVAN key. This
function toggles between enabled (YES) and
disabled (NO). Default value is enabled (YES).

Maximum Level in Spin
Function 230
This function sets the maximum water level
during execution of a spin. If you do not wish
to modify the value, press RESET. If you want
to modify the value, press ENTER, followed by
the new value, then ENTER again to confirm.
Allowed values are from 2 to 60 cm.

DO NOT MODIFY
WITHOUT CONSULTING
B&C TECHNOLOGIES OR A
QUALIFIED SERVICE
TECHNICIAN! EXTREME
MACHINE DAMAGE CAN
OCCUR!

Software Version
STOP + RESET
Pressing the STOP and RESET keys
simultaneously displays the installed firmware
version.

Cylinder Speed
INS
Pressing the INS key during execution of a
wash program displays the commanded wash
cylinder speed in RPM.