4

To perform these functions, press START and RESET together, then at the
prompt (n?), key in the desired number, the press ENTER. Detailed
explanation of each function starts on page 25.

Highlighted items are safety related and SHOULD NOT BE
CHANGED!

DO NOT ALTER THESE VALUES WITHOUT CONSULTING B&C
TECHNOLOGIES OR A QUALIFIED TECHNICIAN!

12 Programming cycles
27 Creation of Programs
45 Programming motors

144 EL6 Win communications mode

118 Disable Machine (Display shows ! - exclamation point)
181 Resets controller - erases all memory
201 Language option (1 - Italian, 2 - English, 3 - German, 4 - Spanish, 5 - French)
205 16 or 24 outputs (B&C uses the 24 output version)
207 Maximum RPM
209 Temperature Hysterisis (min 1 deg, max 10 deg) Default is 3 deg.
210 Display temperature in degrees C
211 Display temperature in degrees F
212 Maximum water level that can be set (10 - 100 cm)
213 Minimum water level for heating (2 - 30 cm)
214 Display number of hours of operation
215 Display total number of washes
216 Display number of washes since the last maintenance

217 Reset maintenance request

218 Display and set number of washes until maintenance request
219 Spin slow down time (40 - 200 sec)
220 Erases Programs and cycles
221 Copy from control to memory card
222 Copy from memory card to control (only programs and cycles)
223 Copy from memory card to control (programs, cycles, and parameters)
225 Disables Advance Key
230 Maximum water level allowed during spin (2 - 60 cm)

P r o g r a m m i n g