1 introduction, 2 model identification, Model nomenclature – Bradford White BNTV-600 User Manual

Page 5

Advertising
background image

Page 1

BRUTE ELITE

Section 1 -

GENERAL INFORMATION

WARNING

Brute Elite units

must be installed in accordance

with the procedures detailed in this manual, or the

Bradford White Corp. warranty will be voided. The

installation must conform to the requirements of

the local jurisdiction having authority, and, in the

United States, to the latest edition of the National

Fuel Gas Code, ANSI Z223.1/NFPA54. In Canada,

the installation must conform to the latest edition

of CSA B149.1 Natural Gas and Propane Gas

Installation Code, and/or local codes. Where required

by the authority having jurisdiction, the installation

of Brute Elite boilers must conform to the Standard

for Controls and Safety Devices for Automatically

Fired Boilers, ANSI/ASME CSD-1. Any modifications

to the boiler, its gas controls, or wiring may void the

warranty. If field conditions require modifications,

consult the factory representative before initiating

such modifications.

1.1 Introduction

This manual provides information necessary for the
installation, operation, and maintenance of the Bradford White
Brute Elite. Read it carefully before starting the installation.

All application and installation procedures should be reviewed
completely before proceeding with the installation. Consult
the Bradford White factory, or local factory representative,
with any problems or questions regarding this equipment.
Experience has shown that most operating problems are
caused by improper installation.

The Brute Elite is protected against over pressurization. A
pressure relief valve is included with each Brute Elite. Some
Brute Elites may require that the PRV be installed prior to

filling the system. Refer to Figures 1-7 for PRV locations.

DANGER

The inlet gas pressure to the appliance must not

exceed 13” W.C. (3.2kPa).

All installations must be made in accordance with 1)

American National Standard Z223.1/NFPA54-Latest Edition

“National Fuel Gas Code” or 2) CSA B149.1 “Natural Gas

and Propane Installation Code” and with the requirement of
the local utility or other authorities having jurisdiction. Such
applicable requirements take precedence over the general
instructions contained herein.

All electrical wiring is to be done in accordance with the local

codes, or in the absence of local codes, with: 1) The National

Electrical Code ANSI/NFPA No. 70-latest Edition, or 2)

CSA STD. C22.1 “Canadian Electrical Code - Part 1”. This
appliance must be electrically grounded in accordance with
these codes.

1.2 Model Identification

Consult the rating plate on the unit. The following information
describes the model number structure.

(1-3)

Model Series Designation

B N T = Brute Elite

(4)

Usage

H = Hydronic

V = Volume Water

(5-7)

Size

0 8 0 = 80,000 BTU/hr input

1 0 5 = 105,000 BTU/hr input

1 5 0 = 150,000 BTU/hr input

1 9 9 = 199,000 BTU/hr input

2 1 0 = 210,000 BTU/hr input

2 8 5 = 285,000 BTU/hr input

3 9 9 = 399,000 BTU/hr input

5 0 0 = 500,000 BTU/hr input

6 0 0 = 600,000 BTU/hr input

7 5 0 = 750,000 BTU/hr input

8 5 0 = 850,000 BTU/hr input

(8)

Fuel

N = Natural Gas

P = LP Gas

(9)

Options Code

X = Standard Unit

J = CSD-1, FM, GAP, IL Code

(size 500-850 only)

(10)

Pump Options

N = Pump included

(80-500 only)

X = No pump

(configuration available for all sizes)

(11)

Revision

3 = Third version

BNTH only

BNTH only

BNTV only

BNTH only

Model Nomenclature

1

2 3

4

SERIES

B N T

B N T

3

USAGE

H - HYDRONIC
V - VOLUME

WATER

SIZE

MBTU/h

0 8 0

1 0 5

1 5 0

1 9 9

2 1 0

2 8 5

3 9 9

5 0 0

6 0 0

7 5 0

8 5 0

FUEL

N - NATURAL
P - PROPANE

OPTIONS CODE

X - STANDARD
J - CSD-1,

FM, GAP,

IL

(500-850 only)

PUMP OPTIONS

N - PUMP INCL.

(80-500 only)

X - NO PUMP

REVISION

3 - THIRD

REG DESIGNATION

B

B - INTERNAL USE

12

5

6

7

8

9

10

11