Hit Products Pro-Two User Manual

Page 18

Advertising
background image

WWW.RAINPROCO.COM

6

PRO 2

WWW.RAINPROCO.COM

Position 8

Use set 1 to choose the program desired, use set 2 to turn a program ON or OFF (a fully
programmed program can be disabled by the this function) use set 3 to turn the master
valve or pump start ON or OFF during the program running, use set 4 to increase or de-
crease the budget feature of the program 0%-250%. (The amount of time in position 2
will not change in the display but the actual run time will be increased or decreased by
the amount of budget %). The new “water budgeted” run times can be viewed in position
5.
Note: The water budget is the fourth leg of the Diamond Settings (see page for more on
the Diamond Settings).

Position 9

Use set 1 to set run time in minutes, use set 2 to set run time of seconds for test cycle,
and use set 4 to turn ON or OFF test cycle.
The controller will immediately run each valve in sequence for the predetermined run
time for visual review of the systems operation.
Note: The Master Valve setting and the pause option value for program 1 will be used
for the test cycle.

Position 10
Semi/ Manual/ Program Clear/Master Clear
Semi- Use set 1 to choose the program you want to activate for one cycle, use set 2 to
activate that program ON. Leave the dial in number 10 position. [Rotating the dial will
cancel the program.]
At the conclusion, the controller will revert to automatic after 30
minutes, without putting the rotary switch back to “Run”.
Note: Within 30 minutes after the conclusion of the selected program the controller will
automatically revert to the “RUN” condition.

Program/Master Valves ON/OFF
Pump Start
Water Budget 0% - 250%

Test Cycle

Semi/ Manual/ Program Clear/Master Clear

Advertising