TROUBLESHOOTING HINTS FOR PRO 2 TWO WIRE SYSTEMS

PROBLEM

SOLUTION

Display Blank

No Power

1) Check: 110v or 220v supply and connec-
tions. Correct as needed
2) Check: 12 V Power at the controller
board terminals.

Controller Operates in “Manual” or “Test”
but not in “Auto”

Incorrect Programming
Controller is OFF

Correct Programming
See the Programming section of this
Manual

Controller Displaying “Short Line” or Turn-
ing ON/OFF and “Clicking”

1) Possible failed Decoder
2) Field wires shorted

No Valves Activating

1) See “Controller Operates in Manual and
Test but not Auto” Line
2) Check the “Out” wire connections at the
Controller.
3) Failed Controller Replace Panel

Single Valve not Activating

1) Check Decoder Wire Connection
2) See Decoder Operation

Multiple Valves not Activating

1) Check wiring and connections between
the last valve working and the first valve
not working.

Display reads “Rain Off”

Controller is in Rain Off condition

1) Rain Switch has activated a bad connec-
tion from Controller to Rain Switch

PROBLEMS

SOLUTIONS

Display is flashing “Rain Off”

Incorrect Rain Switch

Controller displaying reads “Valve Short”
with a valve number

High current draw during valve run time

1) Possible bad solenoid

High current draw during valve run time

1) Possible bad solenoid

2) Shorted wires between decoder
and solenoid

Display frozen, does not respond to rotat-
ing valve

Micro is locked

1) Turn power off for a minute, then back on

Valves Turning ON/OFF during run time

Possible EMF interference

Valves Turning ON/OFF during run time

Possible EMF interference

Check: Controller, Decoder and Field Wir-
ing location in respect to any high voltage.