Hit Products Pro-Two User Manual

Page 8

Advertising
background image

WWW.RAINPROCO.COM

6

PRO 2

WWW.RAINPROCO.COM

INSTALLING THE PRO 2
Mounting the controller...........When selecting the controller installation location, make
sure controller and all related wiring is a minimum of 15 feet from any high voltage

sure controller and all related wiring is a minimum of 15 feet from any high voltage

control boxes, pumps or any high voltage equipment. This irrigation controller is

control boxes, pumps or any high voltage equipment. This irrigation controller is

a computer and should be installed accordingly.

a computer and should be installed accordingly.

When mounting the PRO 2 indoors, notice the “keyhole” shaped mounting slot as well

When mounting the PRO 2 indoors, notice the “keyhole” shaped mounting slot as well

as 2 mounting holes on the back of the controller. Use the template provided to locate
mounting screw location. To attach to wall studs, use a #8 screw, leaving 1/4” of the
shank exposed to slip into the “keyhole” slot.
When mounting the PRO 2 outdoors, use the same procedure as above. When attach

When mounting the PRO 2 outdoors, use the same procedure as above. When attach

-

ing the controller to hollow walls, masonry, or cinder blocks, use appropriate toggle bolts,
masonry shields or compression drive bolts. For additional weatherproofing, run a silicon
bead around the case between the controller and the wall. It is also recommended to fill
mounting holes with silicon as well, to prevent water or insects from entering the control-
ler.
Please read the entire operational manual before installing and programming the

Please read the entire operational manual before installing and programming the

PRO 2 Controller.

PROGRAMMING THE PRO 2 Controller
The PRO 2 Controllers are so easy to program because the four sets of blue up/down
arrow buttons correspond to whatever is directly above them in the display. You can
toggle between ON and OFF, set hours, minutes, and seconds, or even select program
numbers, valve numbers, and start times simply by using these up/down buttons located
directly under their functions.

Each set (two buttons) of buttons operates the display up or down for ease of getting to
the function, number, valve or time desired. For ease of explanation, the following termi-
nology will be used throughout these instructions. The set of buttons to the far left will be
button set 1, directly right of these will be

, directly right of set 2 will be set 3 and

the last set or far right set will be

. The main rotary dial has 12 positions just like

the numbered hour positions on a clock 1-12. The rotary switch consists of the following
positions and functions:

NOTE:
With a new installation be sure to do a “Master Clear” before programming. Rotate the
Dial to position 10. Using the set 4 arrow buttons press the up arrow button under
CLR/OFF” on the Display. The Display will change. Press the same arrow button, under
the word “Yes” again. The display will prompt you to. “Please Wait”. When the display
changes. Rotate the Dial to start programming.

Advertising