4alarm output configuration, Alarm output configuration -10, Table 5. alarm output definitions -10 – CANOGA PERKINS L351 10/100BASE Media Converter User Manual

Page 29: 4 alarm output configuration

Advertising
background image

EdgeAccess Universal Chassis System

L351 10/100BASE Media Converter

4-10

TRAP CONFIGURATION

1) Master Trap Control

Disabled

2) Extension Port Link Traps

Enabled

3) Remote Fault Received Traps

Enabled

4) Link Loss Forwarding Traps

Enabled

5) Link Loss Echo Traps

Enabled

6) Remote User Port Link Traps

Enabled

7) Local User Port Link Traps

Enabled

8) Configuration Traps

Enabled

9) Power/Fan/Temperature Traps

Enabled

10) Cold Start Traps

Enabled

11) Side Band Mgmt Channel Traps

Enabled

12) Alarm Input Traps

Enabled

13) Diagnostics Traps

Enabled

14) Authentication Traps

Disabled

Figure 21. Trap Configuration Screen

4.5.4 Alarm Output Configuration

Use the Alarm Output Configuration screen to set any or all alarms to Major, Minor, or Off. See
Figure 22 and Table 5. To configure alarms, follow these steps:

1. From the Main Menu type

3

, "Alarm Output Configuration," and press <Enter>. The Alarm

Output Configuration screen appears.

2. Type the number for the alarm you want to set and press <Enter>.

3. Press <Space> to cycle to Major, Minor, or Off, and press <Enter>.

ALARM OUTPUT CONFIGURATION

1) Factory Defaults

2) Link Down Alarm

Off

3) RMTF Alarm

Off

4) LLF Alarm

Off

5) Configuration Alarm

Off

6) Power/Fan/Temperature Alarm

Minor

7) SBMC Loss Alarm

Off

8) Power-On Self Test Alarm

Off

Figure 22. Alarm Output Configuration Screen

Table 5. Alarm Output Definitions

Alarm

Description

2) Link Down

Loss of Signal (electrical)/Composite Loss of Signal (optical); one
or both received signals fail; default is Off

3) RMTF

Remote fault received; default is Off