1ping generation, 1 ping generation -21, Table 9. utilities menu options -21 – CANOGA PERKINS L351 10/100BASE Media Converter User Manual

Page 40

Advertising
background image

EdgeAccess Universal Chassis System

L351 10/100BASE Media Converter

4-21

UTILITIES

1) Set Date and Time
2) Reset Configuration To Default
3) Reset Remote Configuration To Default
4) Remote Craft Port:

Enabled

5) Modem/Slip/PPP Baud Rate

19200

6) Modem Initialization String

AT

7) PING generation
8) Static ARP Table
9) Dynamic ARP Table

Figure 35. Utilities Menu Screen

Table 9. Utilities Menu Options

Item

Definition

1) Set Date and Time

Change the time and date information for the modem if needed; if in
a chassis with a DMM, the DMM date and time overrides the L351

2) Reset Configuration
To Default
3) Reset Remote
Configuration To Default

Restores all configurable settings to the defaults except for: date
and time; password; BOOTP; Telnet timeout

4) Remote Craft Port

Enable or disable the console port on the remote module

5) Modem/Slip/PPP Baud
Rate

Select the baud rate, 9600, 19200, 38400, 57600, or 115200 bps for
the modem/SLIP/PPP serial port

6) Modem Initialization
String

The default string is "

AT

"

7) PING Generation

Access the PING diagnostics screen

8) Static ARP Table

Set or change specific IP and MAC addresses

9) Dynamic ARP Table

View current IP and MAC addresses

4.10.1

PING Generation

Use the PING Generation screen to test the connection to a specific IP address. See Figure 36.

PING Generation

IP Address to PING: 0.0.0.0
PING count (1 to 255, 0 = forever):

0

Figure 36. PING Generation Screen

To use PING to check a connection, follow these steps:

1. From the Main Menu, type

7

, "Utilities," and press <Enter>.